beautypg.com

Meters, Weight – Dan Dugan Sound Design Dugan-VN16 User Manual

Page 52

background image

Dugan-VN16 User Guide

52

Meters

The meters have three display modes.

Table 4-1 Meter modes

The default meter display is

auto mix gain

. This is the most useful choice during normal

operation; the input and output meters are only used when setting or checking levels.

Click on the Master

meters

button to toggle through the three meter display modes.

Weight

The

weight

controls set the side-chain levels for each channel into the control system.

This establishes the relative sensitivity of the automatic mix for the channels in use.
They do not change the mix levels. When the

weight

controls are balanced, each mic has

an equal opportunity to take over the system: when one person talks into one mic,
he/she gets all the

auto mix gain

and the others get turned down.

Figure 4-8 Weight controls

The

weight

controls should be used to balance the channel

auto mix gain

indicators

when no one is talking. If a board preamp trimmer is turned down, that channel’s

weight

control can be turned up to re-balance the automixing, and vice-versa.

Weights can be changed by dragging the sliders or by entering dB values in the win-
dows below the sliders. Ctrl-click the

weight

slider to reset its value to 0.

Touch and hold the

weight slider to reset its value to 0.

Meter Displays

Meter Color

auto mix gain

action of the Dugan Speech System

green

input

input level

yellow

output

output level

blue

iPad