CIRCUTOR CIRLAMP Series User Manual
Page 94

9.3.- CirLAMP Node 1 ... 10 V
AC power supply
Mode
Self-powered
Rated voltage
184 ... 276 V ~
Frequency
50/60Hz
Consumption
2W 16VA
Installation category
CAT III 300 V
Voltage measurement circuit
Voltage measurement margin
184 ...276 V ~
Input impedance
600 MΩ
Installation category
CAT III 300 V
Current measurement circuit
Current measurement margin
0.1 ... 3A
Minimum measurement current (Istart)
0.08 A
Installation category
CAT III 300 V
Measurement accuracy
Voltage measurement
< 5% of full-scale
Current measurement
< 5% of full-scale
Active and reactive power measurement
< 5% of full-scale
Outputs 1 ��� 10V (In accordance with EN60929:2011)
Output voltage
1 ... 10V
Current
10
μ ... 2 mA
PLC (Power Line Communications)
Hardware
CENELEC B DCSK
Baud rate
2400 bauds with repeater management
Protocol
CirPLC (DCSK)
Insulation
Alternating voltage
4 kV RMS 50 Hz for 1 minute
Overimpulse
1.2/50 μs 0R source impedance
2 kV UNE-EN 61000-4-5:2007 + CORR:2010
Environmental features
Operating temperature
-25ºC... +70ºC
Storage temperature
-35ºC... +80ºC
Relative humidity (non-condensing)
5 ... 95%
Maximum altitude
2000 m
Protection degree
IP65
Mechanical features
Dimensions (mm)
Weight
250 gr
Enclosure
Polycarbonate
94
CirLAMP system