beautypg.com

CIRCUTOR CIRLAMP Series User Manual

Page 41

background image

Container element: < L07/E07>

< L07/E07> is the container element for information relating to alarm adjustment:

Table 36:File E07-L07, element

Attribute

Description

ActDate

Order activation date.

Container element: < Node>

< Node> is the container element for information relating to a node:

Table 37:File E07-L07, element

Attribute

Description

nodeId

Node identifier.

Container element: < Alarms>

is the container element for information relating to the adjustment of a node's

alarms:

Table 38:File E07-L07, element

Attribute

Description

blinkActive

Threshold of active power for the intermittent bulb alarm.

blinkTime

Blinking time for the intermittent bulb alarm (seconds).

blinkTimes

Number of blinks for the intermittent bulb alarm.

blinkTotalTime

Total blinking time for the intermittent bulb alarm (seconds).

brokenActive

Threshold of active power for the burnt out lamp alarm.

brokenTime

Alarm time for the burnt out lamp (seconds).

capacitorReactive Threshold of reactive power for the broken capacitor alarm.
capacitorTime

Broken capacitor alarm time (seconds).

powerLamp

Lamp power

timeAlarm

Alarm detection time (seconds).

percentageAlarm

Minimum percentage to detect the alarm.

factorPower

Minimum power factor to detect the alarm.

4�6�4�8� E08-L08, Delete nodes from the network

Format of file

E08 (

Figure 39

):

nodeId=”2000002”/>

Figure 39: File E08�

41

Instruction Manual

CirLAMP system