12.6 Application of Virtual COM Port

Application

Through the virtual COM port, IFD9507 is able to transmit the data sent to RS-232 to the
Ethernet by connencting to the software supporing serial ports, e.g. Delta’s WPLSoft,
VFDSoft and ASDA-Soft. See the example below for how to connect IFD9507 to VFD-E AC
motor drive through the virtual COM port by VFDSoft.

Steps

(1) Select “User Define” protocol and set the parameters in the serial master and serial slave

to the ones consistent with those in VFD-E.

(2) Set up virtual COM port.
(3) Open Delta VFDSoft, set up the communication format (COM Setup) and establish the

connection.

1. Setting up Virtual COM Port

„

For the COM setting, select “User Define” and set the communication parameters to the ones

consistent with those in VFD-E.

„

Switch to “User Define” page and select “Listen Port”.