Ethernet Communication Module IFD9507

DVP-PLC Application Manual

21

General

Status

Extended Status

Explanation and Description

0x01

0x0114

VENDOR ID OR PRODUCT CODE MISMATCH
The Product Code or Vendor Id specified in the electronic key
logical segment does not match the Product Code or Vendor Id of in
the target device.

0x01

0x0115

PRODUCT TYPE MISMATCH
The Product Type specified in the electronic key logical segment
does not match the Product Type of in the target device.

0x01 0x0116

REVISION

MISMATCH

The major and minor revision specified in the electronic key logical
segment does not correspond to a valid revision of the target
device.

0x01

0x0315

INVALID SEGMENT IN CONNECTION PATH
Invalid Segment Type or Segment Value in Connection Path This
extended status code is the result of a device being unable to
decode the connection path. This could be caused by an
unrecognized path type, a segment type occurring unexpectedly, or
a myriad of other problems in the connection path.

10 Setting up the Software - DCISoft

This section gives instructions on how to set up IFD9507 by DCISoft and explanations on each setup page.

IFD9507 is set up by UDP port 20006; therefore, you have to be aware of the relevant settings of the firewall.

See the explanations below on the software.

10.1 Setting up Communication & Searching for Modules in DCISoft

„

Broadcast

search

1. Open DCISoft on the PC and click on the “IP Search” icon.

2. You will see the network modules found.