beautypg.com

Power measurement, Power measurement –22 – Altera Transceiver Signal Integrity Development Kit, Stratix IV GT Edition User Manual

Page 32

background image

2–22

Chapter 2: Board Components

Components and Interfaces

Transceiver Signal Integrity Development Kit,

November 2011

Altera Corporation

Stratix IV GT Edition Reference Manual

Power Measurement

Figure 2–8

shows the block diagram for the power measurement circuitry.

The power measurement is provided for six FPGA power rails (0.95-V V

CC

core plus

the transceiver power rails—V

CCR

, V

CCT

, V

CCL

, V

CCH

, and V

CCA

). The power

measurement is implemented by a multi-channel differential 24-bit Linear Technology
LT2418 (U14) delta-sigma analog-to-digital converter (ADC) and sense resistors to
measure the small voltage drop across the resistors. This ADC connects to the FPGA
via a serial peripheral interface (SPI) bus. The FPGA handles all power measurement
processing and display to the LCD. A rotary switch (SW16) controls the selection of
specific power rail to be displayed on the LCD.

Table 2–22

lists the power rails being

measured along with the value of the sense resistor used for each rail.

Figure 2–8. Power Measurement Circuit

Stratix IV GT

FPGA

(U33)

SPI Bus

LTC2418

(U14)

0p95V

R3

Reg

(U1)

R20

Reg

(U6, U8)

R25

Reg

(U11)

Reg

(U10, U12)

R24

R11

Reg

(U4)

V

CCR

V

CCL

V

CCH

V

CCA

R21

Reg

(U7, U9)

V

CCT

Table 2–22. Power Rail Measurements

Power Rail

Voltage (V)

Board Reference

Rsense (

Ω)

V

CC

and V

CCHIP

0.95

R3

0.001

V

CCR

1.2

R20

0.009

V

CCT

1.2

R21

0.009

V

CCL

1.2

R25

0.009

V

CCH

1.4

R24

0.009

V

CCA

3.3

R11

0.009