Power measurement, Power measurement –22 – Altera Transceiver Signal Integrity Development Kit, Stratix IV GT Edition User Manual
Page 32

2–22
Chapter 2: Board Components
Components and Interfaces
Transceiver Signal Integrity Development Kit,
November 2011
Altera Corporation
Stratix IV GT Edition Reference Manual
Power Measurement
shows the block diagram for the power measurement circuitry.
The power measurement is provided for six FPGA power rails (0.95-V V
CC
core plus
the transceiver power rails—V
CCR
, V
CCT
, V
CCL
, V
CCH
, and V
CCA
). The power
measurement is implemented by a multi-channel differential 24-bit Linear Technology
LT2418 (U14) delta-sigma analog-to-digital converter (ADC) and sense resistors to
measure the small voltage drop across the resistors. This ADC connects to the FPGA
via a serial peripheral interface (SPI) bus. The FPGA handles all power measurement
processing and display to the LCD. A rotary switch (SW16) controls the selection of
specific power rail to be displayed on the LCD.
lists the power rails being
measured along with the value of the sense resistor used for each rail.
Figure 2–8. Power Measurement Circuit
Stratix IV GT
FPGA
(U33)
SPI Bus
LTC2418
(U14)
0p95V
R3
Reg
(U1)
R20
Reg
(U6, U8)
R25
Reg
(U11)
Reg
(U10, U12)
R24
R11
Reg
(U4)
V
CCR
V
CCL
V
CCH
V
CCA
R21
Reg
(U7, U9)
V
CCT
Table 2–22. Power Rail Measurements
Power Rail
Voltage (V)
Board Reference
Rsense (
Ω)
V
CC
and V
CCHIP
0.95
R3
0.001
V
CCR
1.2
R20
0.009
V
CCT
1.2
R21
0.009
V
CCL
1.2
R25
0.009
V
CCH
1.4
R24
0.009
V
CCA
3.3
R11
0.009