9 Project window

9.5.4

Expansion card PMCprimo

If a PMCprimo MC1P expansion card is installed in the servo amplifier (servo amplifier edition
PMCprimo Drive2/3) several parameters have to be set on defined values and therefore they
cannot be edited by the user. When connecting PDrive to the servo amplifier those parameters
are checked and set automatically on their defined values. After that the access to these
parameters is denied for the user. The following message appears while saving the parameters
on the servo amplifier:

PMCprimo default values:

- Analog Outputs 1 / 2:

ANOUTx

= 6

- Digital Inputs 1 / 2 / 3 / 4:

INxMODE

= 0

- Setpoint Ramp + / -:

ACC / DEC

= 1

- Ambient Temperature Switch off Threshold

MAXTEMPE = 65

- FPGA functionality

FPGA

= 0

- Source for fieldbus synchronization

SYNCSRC

= 0

Attention:
The automatically loading of PMCprimo default values can be deselected in the menu „Tools“
-> „Options“.

Changing the PMCprimo default values can cause unexpected effects in the amplifier!