9 Project window

9

Project window

9.1

Setup

9.1.1

Basic setup

Regeneration resistor [

PBALRES

]

Internal

The internal regeneration resistor is used.

External

An external regeneration resistor, connected to the terminals +R

bext

and -R

B

, is

used.

Ohm - PMCtendo DD5 and PMCprotego D only
Sets the value of the regeneration resistor in unit Ohm.

Max. Regeneration Power [

PBALMAX

]

Set the maximum Regen Power.

Max. Mains Voltage [

VBUSBAL

]

This parameter is used to adjust the regeneration and switch-off levels of the servo amplifiers to
suit the mains power supply voltage or the system conditions for multi-axis systems with
parallel-connected DC-link circuits.

Response to Loss of Input Phase [

PMODE

]

Handles the message „Phase missing“.

Hardware [

HVER

]

Display the version and revision level of the servo amplifier hardware.

Firmware [

VER

]

Display the version and revision level of the servo amplifier firmware.

Name [

ALIAS

]

Here you can assign a name (8 chars max.) to the servo amplifier.

Serial Number [

SERIALNO

]

Display the serial number of the servo amplifier.

Run Time [

TRUN

]

Display the operational time of the servo amplifier, saved at 8 min. intervals.