9 Project window

9.2.1.4

Homing type 2

Homing with limit switches, without homing switch, with feedback zero

Negative traverse, positive count direction

Positive traverse, positive count direction

The meanings of the abbreviations in the drawings are:

N

Limit switch NSTOP

P

Limit switch PSTOP

SP

Start position

R

Homing switch

vref

preset velocity

NM

feedback zero mark