9 Project window

Number of multi-turn bits [

SSIREVOL

] – PMCtendo DD5 and PMCprotego D only

Defines the number of multi-turn bits in an SSI communication.

Number of SSI bits to read [

SSIRXD

] – PMCtendo DD5 and PMCprotego D only

Establishes the number of SSI bits to read

Resolver Signal [

RK

]

The RK parameter can be used to correct any amplitude difference that may exist between the
sine and cosine signals from the resolver.

Press the button “Calculate RK” for automatic calculation.

No overvoltage surveillance [DRVCONFIG] (Bit 6)
Monitoring of the maximum voltage of the sine/cosine encoder at X1 is deactivated.

No overflow surveillance [DRVCONFIG] (Bit 7)
Overflow monitoring of a multi-turn encoder is switched off.

Single turn executed as multi turn encoder [DRVCONFIG] (Bit 8)
A single-turn encoder is treated as a multi-turn encoder. The absolute position within a
revolution is taken on power-up. A reference run is not required.

Angle of rotation
Shows the mechanical angle of rotation.