background image

9 Project window

9.2.1.2

Homing type 0

Sets the reference point to the setpoint position (the following error is lost). The load
does not move.

9.2.1.3

Homing type 1

Before starting homing, check the safety of the system since the load may move even if
the limit-switches are disconnected or defective.

Homing without limit switches, with homing switch, with feedback zero:

Negative traverse, positive count direction,

Negative traverse, negative count direction

Homing with limit switches, with homing switch, with feedback zero

Negative traverse, positive count direction

Positive traverse, positive count direction

The meanings of the abbreviations in the drawings are:

N

Limit switch NSTOP

P

Limit switch PSTOP

SP

Start position

R

Homing switch

vref

preset velocity

NM

feedback zero mark