beautypg.com

Pilz PMCprimo DriveP.12/AA0/4/0/0/208-480VAC User Manual

Page 20

background image

9 Project window

9.1.3

CAN/Fieldbus

Address [

ADDR

]

The entry is the station address (1...63) of the servo amplifier. This number is required by the
fieldbus and for the parameter setting of the servo amplifier in multi-axis systems for an
unambiguous identification of the servo amplifier within the system.

External Watchdog [

EXTWD

]

Definition of the monitoring (watchdog) time for fieldbus/slot communication. This monitoring is
only active when the value is greater than 0 and the output stage is enabled.

Source for fieldbus synchronization [

SYNCSRC

]

Defines the synchronisation source, if the control loop is synchronised via an interface.

FPGA functionality [

FPGA

] – PMCtendo DD4 only

Defines the FPGA program that is to be loaded in the initialisation phase.

Baud Rate CAN open [

CBAUD

]

The entry is the transmission rate of the servo amplifier.

Page 20

User Manual for Setup Software PDrive

This manual is related to the following products: