8 Use

8.3.4

Service bar

With the service bar you have a direct access to important service functions of the servo
amplifier.

PTerm:
Starts PTerm.exe.

PScope:
Starts PScope.exe.

PEdit:
Starts PEdit.exe.

Save:
Saves the current parameter/motion task data set to a data medium (hard drive, floppy disk). If
the data set does not yet have a file name, you will be prompted to enter a name and storage
location.

Load:
Opens a parameter file: A parameter data set is read from the data medium (hard drive, floppy
disk). If there is an active connection, the data set is downloaded to the servo amplifier.

Save data in EEPROM:
Non-volatile storage of the currently valid parameter set in the EEPROM of the servo amplifier.
In this way you can permanently save all the parameter changes that you have made since the
last switch-on/reset of the servo amplifier.

Load default parameters to RAM / EEPROM:
Cancel all the parameters that have been set up, and load the manufacturer’s default values.

STOP amplifier:
Stop the currently active service function and disables the power stage.

ENABLE:
Enables the power stage.

DISABLE:
Disables the power stage.

RESET amplifier:
Software-reset of the servo amplifier.

Clear Fault:
Clear the present errors and warnings.