Device commands, Vi. command line interface (cli) protocol, Continued) – SurgeX SX-AX20 User Manual
Page 17

Page 16
SX-AX15 (20) User Manual
VI. Command Line Interface (CLI) Protocol
(continued)
Device Commands
Command
Description
Admin
Fact Def
get devices
get all
get outlets
This command displays a list of connected devices and their current
status.
No
get device <#1
‐#16 | devname>
Get device information. Displays the device name and all outlet
names and current status.
Yes
Axess
set device <#1
‐#16 > name
Set the name of the selected Axess. 20 characters max.
get cycle
Get or set the cycle time in seconds.
No
10
set cycle <1
‐99>
get delay
Get or set the delay time in seconds.
No
1
set delay <1
‐99>
get power
Get the current power draw and energy used since the last counter
reset. The energy counter can be reset via SCU or web page, and
will also reset after a reboot.
Yes
get current
Get the measured current of the local Axess.
Yes
get device <#1
‐#16 | devname> current
Get the measured current of the selected Axess.
Yes
get current alarm
High and Low current alarms are used to monitor current conditions
and send an alert by email, SNMP and syslog when the high or low
thresholds are exceeded.
High current alarms will also result in all outlets being turned off until
manually turned back on.
From 0.0 to 15.0/20.0 Amps (depending on max current for device)
in 0.1 Amp increments.
Yes
Highalarm:
15.0 for 15
Amp Models
20.0 for 20
Amp Models
Lowalarm:
0.0 Amp
get device <#1
‐#16 | devname> current alarm
set main a hcalarm
set device <#1
‐#16 | devname> main a
hcalarm
set main a lcalarm
set device <#1
‐#16 | devname> main a
lcalarm