beautypg.com

SurgeX SX-1120-RT User Manual

Surgex, Installation instructions

background image

SurgeX

Installation Instructions

SX1115RT and SX1120RT



Mounting

The SurgeX SX1115/1120RT are designed to be installed in a 19 inch equipment
rack and require one unit (1-U) of rack space. Remove the product from its
packaging and slide it into place in the rack being careful to feed the power cord
into the rack first and guide it so that it does not get caught or jammed as the
product is installed. Use the four screws provided with the product to secure the
rack ears to the rack rails. These screws can be tightened by hand and do not
require tools.


120 Volt Connections

Connect power to the unit by plugging the cord into a 120V ac receptacle. The
SX1120RT must be plugged into a 20 amp receptacle. If a 120V, 20 amp
receptacle is not available, you will need to have one installed by a licensed
electrical contractor.

The SX1115/1120RT have a total of 9 receptacles: six switched, two always on
and a front panel courtesy outlet. Each receptacle is rated for a maximum load of
15 amps, but the total load must not exceed 15 amps for the SX1115RT and 20
amps for the SX1120RT. Plug the equipment cords into the always-on and
switched receptacles as needed to power the equipment.

The always-on and courtesy receptacles provide power as long as power is
supplied to the SurgeX and the AC voltage is within normal limits. The six
switched outlets provide power only when the front panel switch is on and the
remote control input is also activated.