beautypg.com

6100 data file naming convention, 6100 calorimeter run data template, Generic interface – Parr Instrument 6100 User Manual

Page 59: Communications interfaces

background image

Communications Interfaces

6100

D

w w w . p a r r i n s t . c o m

57

Generic Interface

The data field should consist
of 9 numeric characters (0
through 9, +, - and space)
terminated with a carriage
return (CR). Leading zeros may
be blanked as spaces and are counted. Non-numeric
characters are ignored and will reset the input buffer
if the data field has not been filled. Any characters
received after filling the data field and before the
carriage return are ignored.

Table D-1

6100 Data File Naming Convention

Test data files are named with the following convention.

Test Type

Filename

Preliminary Standardization

.std.plim.csv

Final Standardization

.std.finl.csv

Preliminary Determination

.det.plim.csv

Final Determination

.det.finl.csv

Pre-weigh

.---.pwgh.csv

Table D-2

6100 Calorimeter Run Data Template

Field

Description

SampleID

char[16]

Timestamp

MM/DD/YY HH:mm:ss

Mode

0 = determination, 1 = standardization

Method

0 = equilibrium, 1 = dynamic

State

0 = preweigh, 1 = preliminary, 2 = final

Units

0 = MJ/kg, 1 = Btu/lb, 2 = cal/g,
3 = J/kg, 4 = other

UnitMultIfOther unit multiplier in effect at time of

report

BombID

[1,4]

BombEE

bomb energy equivalent

SampleWt

sample weight

SpikeWt

spike weight

Fuse

fuse value

FuseFinal

fuse value is final

Acid

acid value

AcidFinal

acid value is final

Sulfur

sulfur value

SulfurFinal

sulfur value is final

Hydrogen

hydrogen value (net calc option)

HydrogenFinal

hydrogen value is final (net calc option)

MAD

moisture as determined value (dry
calc option)

MAD Final

moisture as determined is final

JacketTemp

jacket temperature

InitTemp

initial temperature

DeltaT

temperature rise

HOC

gross heat of combustion

NetHOC

dry net HOC (net calc options enabled)

DryHOC

dry gross HOC
(if dry calc option enabled)

DryNetHOC

dry net HOC (if both dry and net calc
options enabled)

Oxygen

oxygen value (net calc option)

Oxygen Final

oxygen value is final

Nitrogen

nitrogen value (net calc option)

Nitrogen Final

nitrogen value is final

MAR

moisture as received (dry calc option)

MAR Final

moisture as received value is final

Dry Net HOC_AR Dry net HOC as received value (if both

dry and net calc option enabled)

Bomb Name

bomb name assigned to bomb ID

Field

Length

data

9

CR

1