ADLINK IMB-S90 User Manual
Page 54

IMB-S90 IPMI User’s Manual
54
3. In the Event Filter Configuration section,
• PEF ID displays the ID for configured PEF entry (read-only).
• In
Filter Configuration, check the box to enable the PEF settings.
• In
Event Severity, select any one of the Event severity from the list.
4. In the Filter Action Configuration section,
• Event Filter Action is a mandatory field and checked by default, which
enable PEF Alert action (read-only).
• Select any one of the Power Action either Power down, Power reset or
Power cycle from the drop down list
• Choose any one of the configured Alert Policy Number from the drop down
list.
Note: Alert Policy has to be configured - under Configuration->PEF->Alert
Policy.
5. In the Generator ID configuration section,
• Check
Generator ID Data option to fill the Generator ID with raw data.
• Generator ID 1 field is used to give raw generator ID1 data value.
• Generator ID 2 field is used to give raw generator ID2 data value.
Note: In RAW data field, to specify hexadecimal value prefix with ‘0x’.
• In
the
Event Generator section, choose the event generator as Slave
Address - if event was generated from IPMB.Otherwise as System Software
ID - if event was generated from system software.
• In
the
Slave Address/Software ID field, specify corresponding I2C Slave
Address or System Software ID.
• Choose the particular Channel Number that event message was received
over. Or choose ‘0’ if the event message was received via the system
interface, primary IPMB, or internally generated by the BMC.
• Choose the corresponding IPMB Device LUN if event generated by IPMB.
6. In the Sensor configuration section,
• Select the sensor type of sensor that will trigger the event filter action.
• In the sensor name field, choose the particular sensor from the sensor list.
• Choose event option to be either All Events or Sensor Specific Events.
7. In the Event Data configuration section,
• Event Trigger field is used to give Event/Reading type value.