ADLINK ETX-PVR User Manual
Page 45

Chapter 3
Hardware
ETX-PVR
Reference Manual
39
17,
18
VCC
DC Power – +5 volts +/-5%
19
OVCR*
Over Current Detect – This signal indicates a USB over-current condition.
20 NC
Not
Connected
21
EXTSMI*
External System Management Interrupt – This signal is provided by external
circuitry to initiate an SMI event with the ETX-PVR.
22
I
2
DAT
This data line implements an I
2
C bus, which supports external slave devices
only. The I
2
C interface supports EEPROMs and other simple I/O devices.
23
SMBCLK
System Management Bus Clock – This signal is used to support internal and
external SMBus devices, such as temperature and battery monitoring.
24
SMBDATA
System Management Bus Data – This signal is used to support internal and
external SMBus devices, such as temperature and battery monitoring.
25 NC
Not
Connected
26
SMBALRT*
System Management Bus Alert – This signal is used by SMBus devices to
signal an event on the SMBus.
27 NC
Not
Connected
28
DASP*
Drive Active/Drive Present – This signal is time-multiplexed and indicates
the drive is present and active. If a Compact Flash is connected to the
baseboard, this signal must be routed to the DASP pin of any other device
connected to the IDE channel. May also be used for Master/Slave negotiation
on the IDE channel.
29 NC
Not
Connected
30 PIDE_CS3*
Primary
Chip
Select 1 – Selects host-accessible Command Block Register.
31 NC
Not
Connected
32 PIDE_CS1*
Primary
Chip
Select 0 – Selects host-accessible Command Block Register.
33,
34
GND
Ground
35
PDIAG
Passed Diagnostics – This signal is used for Master/Slave negotiation on the
IDE channel. It is asserted by the Slave to indicate to master that the slave has
passed its internal Diagnostics command. If a Compact Flash is connected to
the baseboard, this signal must be routed to the DASP pin of any another
device connected to the IDE channel.
May also be used to detect the presence of an 80-conductor IDE cable, which
is required for support of the DMA66 or DMA100 high-speed transfers.
36
PIDE_A2
Primary Drive Address Bus 2 – Used <0 to 2> to indicate which byte in the
ATA command block or control block (register) is being accessed.
37 NC
Not
Connected
38
PIDE_A0
Primary Drive Address Bus 0 – Refer to J4, pin-36, for more information.
39 NC
Not
Connected
40
PIDE_A1
Primary Drive Address Bus 1 – Refer to J4, pin-36, for more information.
41
BATLOW*
Battery Low – This external signal to the ETX-PVR indicates when the
external battery is low.
42 NC
Not
Connected
43 NC
Not
Connected
Table 3-8. Complete X4 Interface Pin Signal Descriptions (J4) (Continued)