51

Appendices

~ Appendix F: Serial Commands

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

OUTPUTMIX=hex word. The selected input will be routed to

the outputs indicated.

OUTPUTMIX=null. Mix Command to return the current

setting for the input.

Note:

When entering the hex value of the , it is not

necessary to add the leading zeros, only zeros that follow the

value, as in examples 1 & 2, below.

Example 1

The following command routes Pregate Mic Input 1 audio to

Output 1. This command applies only to the box the serial cable

connects to, since a device is not specified.

G-Link Z-B

US

G-Link Y

-B

U

S

G-Link X-B

US

Sub B

US 2

Sub B

US 1

Output D

Output C

Output B

Output A

Output 8

Output 7

Output 6

Output 5

Output 4

Output 3

Output 2

Output 1

16 15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

1

1

MTRX 18 1

Bit

Hex=1

Example 1: Outputmix Matrix

Example 2

The following command routes Mic Input 1 Post Gate audio to

Output A, B, and C, and to the G-Link X-bus.

G-Link Z-B

US

G-Link Y

-B

U

S

G-Link X-B

US

Sub B

US 2

Sub B

US 1

Output D

Output C

Output B

Output A

Output 8

Output 7

Output 6

Output 5

Output 4

Output 3

Output 2

Output 1

16 15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

1

1

MTRX 1 4700

Example 2: Outputmix Matrix

Return Values

The command will return the updated matrix condition for the

selected input in the same format as the command was issued.

Bit

Hex=4700