Appendices ~ appendix f: serial commands, Return values – ClearOne AP800 User Manual
Page 55
51
Appendices
~ Appendix F: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
OUTPUTMIX=hex word. The selected input will be routed to
the outputs indicated.
OUTPUTMIX=null. Mix Command to return the current
setting for the input.
When entering the hex value of the
necessary to add the leading zeros, only zeros that follow the
value, as in examples 1 & 2, below.
Example 1
The following command routes Pregate Mic Input 1 audio to
Output 1. This command applies only to the box the serial cable
connects to, since a device is not specified.
G-Link Z-B
US
G-Link Y
-B
U
S
G-Link X-B
US
Sub B
US 2
Sub B
US 1
Output D
Output C
Output B
Output A
Output 8
Output 7
Output 6
Output 5
Output 4
Output 3
Output 2
Output 1
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
MTRX 18 1
Bit
Hex=1
Example 1: Outputmix Matrix
Example 2
The following command routes Mic Input 1 Post Gate audio to
Output A, B, and C, and to the G-Link X-bus.
G-Link Z-B
US
G-Link Y
-B
U
S
G-Link X-B
US
Sub B
US 2
Sub B
US 1
Output D
Output C
Output B
Output A
Output 8
Output 7
Output 6
Output 5
Output 4
Output 3
Output 2
Output 1
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
MTRX 1 4700
Example 2: Outputmix Matrix
Return Values
The command will return the updated matrix condition for the
selected input in the same format as the command was issued.
Bit
Hex=4700