Introduction

~ G-Link Network

6

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

G-Link network architecture allows up to eight AP800s/AP400s and up to 16 AP10

Telephone Interfaces to be controlled as if all were part of a single unit.

Digital technology can provide a distinct advantage in designing and

controlling teleconferencing systems. The ability to network with additional AP

units (for a maximum of 64 mic inputs) makes the Audio Perfect systems ideal for

room combining applications or larger applications which require more

microphone inputs.

The G-Link gives you the ability to interconnect the AP800 with other Audio

Perfect units (additional AP400s, AP10s, and AP800s). The maximum distance

between connected ClearOne units is 20 feet/6.1 meters. ClearOne Communications

recommends that category five twisted-pair (10Base) cable be used. Control of

connected AP800s and AP10s is also possible via a single COM port.

G-Link bus

This digital mix-minus bus appears on every Audio Perfect product. It allows audio

to be routed to any destination on the G-Link network. The AP800 has four digital

buses: X-bus, Y-bus, Z-bus, and G-Link EC Reference bus.

X-bus. This mix-minus bus is defined as the master microphone mix, and it

supports NOM (see page 24). All gated microphones are default routed to

this bus.

Y-bus. This mix-minus bus is defined as the line input master mix. All line-

level audio such as from video codecs, AP400s, AP10 Telephone Interfaces,

VCRs, etc. are default routed to this bus.

Z-bus. This mix-minus bus is a user-defined auxiliary mix bus.

G-Link EC Reference bus. This bus provides a system-wide echo canceller

reference signal. It allows for the reference signal to be passed to additional

G-Linked mic channels and their associated echo cancellers. Typically, one

output on one unit will be passed along the G-Link EC Reference bus.

G-Link Network

A G-Link network will
allow interconnection of
up to eight

AP800s/AP400s and 16 AP10s.

When multiple AP800s
are used in a system, the
gating parameters on all

units must be set the same.