beautypg.com

Gmode, Gratio, Hold – ClearOne AP800 User Manual

Page 50: Appendices ~ appendix f: serial commands, Explanation, Return values

background image

Appendices

~ Appendix F: Serial Commands

46

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

GMODE

This command changes or reports back the gating mode for a

microphone.

[DEVICE] GMODE

Explanation

CH= 1-8 Parameter to apply to the specified microphone

channel

CH= * Parameter to apply command to all microphone

channels

X=1 Parameter to set the state to AUTO

X=2 Parameter to set the state to MANUAL ON

X=3 Parameter to set the state to MANUAL OFF

X=4 Parameter to set the state to OVERRIDE ON

X=5 Parameter to set the state to OVERRIDE OFF

X=Null Parameter to return the current state

Return Values

The command will return the updated condition of the gating

in the same format as the command.

GRATIO

This command changes or reports back the setting of the gate

ratio.

[DEVICE] GRATIO

Explanation

X=0-50 Parameter to set the Gate Ratio (in dB)

X=Null Parameter to return the current gate ratio

Return Values

The command will return the updated gate ratio (0–50) in the

same format as the command.

HOLD

This command changes or reports back the setting of the hold

time.

[DEVICE] HOLD

Explanation

X=100-8000 Parameter to set the hold time (in

milliseconds)

X=Null Parameter to return the current hold time

Return Values

The command will return the updated hold time in the same

format as the command.

LFP

This command locks, unlocks, or returns the current state of

the front panel from the serial port.

[DEVICE] LFP

Explanation

X=0 Parameter to unlock the front panel

X=1 Parameter to lock the front panel

X=2 Parameter to toggle the state from one state to

the other (regardless of current state)

X=Null Parameter to return the current state of the

front panel

Return Values

The command will return the updated condition of the front

panel.