beautypg.com

Control/status a pinout, Appendix d: connector pinouts, Appendices ~ appendix d: connector pinouts – ClearOne AP800 User Manual

Page 40: Safety information

background image

Appendices

~ Appendix D: Connector Pinouts

36

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Control/Status A pinout

Pin Number

Definable*

Status Default Description

1

Yes

C

Lock front panel toggle

2

Yes

S

Status of front panel lock

3

Yes

C

Mute all mics toggle

4

Yes

S

Status of mute all mics

5

Yes

C

Mute A output toggle

6

Yes

S

Status of A output mute

7

Yes

C

Mute B output toggle

8

Yes

S

Status of B output mute

9

Yes

C

Mute C output toggle

10

Yes

S

Status of C output mute

11

Yes

C

Mute D output toggle

12

Yes

S

Status of D output mute

13

Yes

C

Volume Up D Output (1dB)

14 Yes S

Not

Active

15

Yes

C

Volume Down D Output (1dB)

16 Yes S

Not

Active

17

No

S

Mic #1 Gate Status

18

No

S

Mic #2 Gate Status

19

No

S

Mic #3 Gate Status

20

No

S

Mic #4 Gate Status

21

No

S

Mic #5 Gate Status

22

No

S

Mic #6 Gate Status

23

No

S

Mic #7 Gate Status

24

No

S

Mic #8 Gate Status

25 No Ground

Ground

Status Outputs:

DB-25 female; open collector, 40V max, 300mA each

(2) +5VDC, 300mA each 40V

Control Inputs:

Input activation selectable; momentary or latching ground

Safety Information

CAUTION: Users should not attempt to make such connections themselves, but

should contact the appropriate electrical inspection authority, or electrician, as

appropriate.

Appendix D: Connector Pinouts

13

25

1

14

Figure D.1. Control/Status (DB-25)

connector