Error Codes
Error 1
The address is not valid/out of range or an invalid character.
Error 2
Could not extract a command from the string received.
Error 3
Serial overrun.
Error 4
Reserved.
Error 5
Invalid parameter.
Error 6
Unrecognized command.
The command string will then be explained (where necessary), followed by the
returned values and (where necessary) an example.
AP800 Serial Commands
Command Function
AAMB
Enable/disable adaptive ambient*
MDMODE
Enable/disable modem mode
AGC Enable/disable
AGC*
MEQ
Set/report three-band equalization*
AMBLVL
Set/report ambient level
MHP
Enable/disable high-pass filter*
BAUD
Set/report RS-232 port baud rate
MINIT
Set/report modem initialization string
CHAIRO Enable/disable
chairman
override*
MLINE
Set/report mic/line level*
DECAY
Set/report decay rate
MMAX
Set/report max. number/mics
DFLTM
Set/report default meter
MPASS
Program modem password string
EC
Enable/disable echo canceller*
MREF
Set/report echo canceller reference*
ERL
Return ERL for a mic channel*
MTRX
Program/report matrix configuration*
ERLE
Return ERLE for a mic channel*
MUTE
Set/report mute status*
EQ Enable/disable
equalization*
NLP
Set/report nonlinear processing*
FLOW Enable/disable
flow-control
Command Function
NOM
Enable/disable NOM attenuation*
FMP
Enable/disable first mic priority
OFFA
Set/report off attenuation
FPP
Set/report front-panel passcode
PAA
Enable/disable PA adaptive mode
GAIN
Set/report gain setting*
PCMD
Program/report GPIO control pin
GATE
Report mic gating status
PEVNT
Program/report GPIO status pin
GMODE
Set/report gating mode*
PP
Enable/disable phantom power*
GRATIO
Set/report gate ratio
PRESET
Set/report active preset
HOLD
Set/report hold time
REFSEL
Set/report output for EC reference
LFP
Enable/disable front-panel lock
TOUT
Set/report inactivity timeout
LMO
Set/report last-mic-on mode
UID
Returns unit identification number
LVL Report
level*
VER
Return current version of firmware
MASTER
Set/report master/slave settings
* Applied to a specific channel