beautypg.com

Ap800 serial commands, Appendices ~ appendix f: serial commands, Error codes – ClearOne AP800 User Manual

Page 44

background image

Appendices

~ Appendix F: Serial Commands

40

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Note: Using the all-mic toggle might not produce the desired result, depending

on the state the mics are in. For example, if one mic is muted and all other mics

are not, an all-mic toggle would mute all others, but unmute that particular mic.

Error Codes

Error 1

The address is not valid/out of range or an invalid character.

Error 2

Could not extract a command from the string received.

Error 3

Serial overrun.

Error 4

Reserved.

Error 5

Invalid parameter.

Error 6

Unrecognized command.

The command string will then be explained (where necessary), followed by the

returned values and (where necessary) an example.

AP800 Serial Commands

Command Function

AAMB

Enable/disable adaptive ambient*

MDMODE

Enable/disable modem mode

AGC Enable/disable

AGC*

MEQ

Set/report three-band equalization*

AMBLVL

Set/report ambient level

MHP

Enable/disable high-pass filter*

BAUD

Set/report RS-232 port baud rate

MINIT

Set/report modem initialization string

CHAIRO Enable/disable

chairman

override*

MLINE

Set/report mic/line level*

DECAY

Set/report decay rate

MMAX

Set/report max. number/mics

DFLTM

Set/report default meter

MPASS

Program modem password string

EC

Enable/disable echo canceller*

MREF

Set/report echo canceller reference*

ERL

Return ERL for a mic channel*

MTRX

Program/report matrix configuration*

ERLE

Return ERLE for a mic channel*

MUTE

Set/report mute status*

EQ Enable/disable

equalization*

NLP

Set/report nonlinear processing*

FLOW Enable/disable

flow-control

Command Function

NOM

Enable/disable NOM attenuation*

FMP

Enable/disable first mic priority

OFFA

Set/report off attenuation

FPP

Set/report front-panel passcode

PAA

Enable/disable PA adaptive mode

GAIN

Set/report gain setting*

PCMD

Program/report GPIO control pin

GATE

Report mic gating status

PEVNT

Program/report GPIO status pin

GMODE

Set/report gating mode*

PP

Enable/disable phantom power*

GRATIO

Set/report gate ratio

PRESET

Set/report active preset

HOLD

Set/report hold time

REFSEL

Set/report output for EC reference

LFP

Enable/disable front-panel lock

TOUT

Set/report inactivity timeout

LMO

Set/report last-mic-on mode

UID

Returns unit identification number

LVL Report

level*

VER

Return current version of firmware

MASTER

Set/report master/slave settings

* Applied to a specific channel