Installation ~ lcd programming – ClearOne AP800 User Manual

Page 22

background image

Installation

~ LCD Programming

18

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Figure 2.9. Off Attenuation

Hold Time

This feature determines the length of time that a microphone remains On after the

microphone audio level drops below the gate ratio (Figure 2.10 below). Values range

from 0.1–8.0 seconds in one-tenth second increments. Default setting is 0.3. Setting

this value too low might cause the microphones to gate on and off too frequently

during brief pauses of speech. However, setting this value too high might cause too

many microphones to be on at one time.

Decay Rate

This feature determines how fast a microphone gates off after the hold time expires

(see Figure 2.11). Three options are available for this feature: slow (default),

medium, and fast.

Figure 2.10. Hold Time

Time

Figure 2.11. Decay Rate