SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide

Accessing Switch Management

Connecting the Console

The two following subsections explain how to connect to the switch console. You
can connect directly or via a modem. For detailed information on cabling and pins,
see Chapter B, “Cable and Pin Information”.

Connecting a Terminal Directly to the MANAGEMENT Port

1. Connect one end of a crossover TIA/EIA-232 cable (commonly known as a RS-

232 cable) to the MANAGEMENT port. This is a male DB-9 connector
configured as a DTE (Data Terminal Equipment) device.

2. Connect the other end of the cable to a PC or another DTE device.

OR

1. Attach a null-modem adapter to the MANAGEMENT port.

2. Attach a straight-through modem cable to the null-modem adapter.

Connecting to the MANAGEMENT Port Using a Modem

1. Connect one end of a straight-through TIA/EIA-232 modem cable to the

MANAGEMENT port. This is a male DB-9 connector configured as a DTE
device.

2. Connect the other end of the cable to a modem.

See Figure 24 to view the location of the cable connection on the front panel of
the SmartStack STS16-20D/STS16-20R.

Figure 24. View of Console Connection

The next step and table describe the settings to use for configuring a console in
order to communicate with the SmartStack STS16-20D/STS16-20R.