beautypg.com

Isobus job computer : ic18 nh3, Operation, Implement parameters – TeeJet IC18 NH3 JOB COMPUTER User Manual

Page 60: Calibrations, Alarm configurations, Regulation parameters, Implement speed sensor

background image

54

www.teejet.com

ISOBUS Job Computer : IC18 NH3

OVER

VIE
W

SE

TUP

APPENDIX

GE

TTING ST

AR

TED

OPER

ATION

Operation

Description

Factory Setting

Range/Options

User Setting

Application Rate Step

5%

1 - 20

Speed Source

CAN

CAN
Implement
Simulated

Simulated Speed

0.0 mile/h / km/h 0.0 - 99.9

Implement Parameters

Section Width

Description

Factory Setting

Range

User Setting

Section Width

118 in. / 300 cm

1 - 9999

Regulation Parameters

Description

Factory Setting

Range

User Setting

Valve Calibration, Rough

19

1 - 19

Valve Calibration, Fine

9

1 - 9

Calibrations

Implement Speed Sensor

Description

Factory Setting

Range/Options

User Setting

Pulses per Distance

0

0 - 33445

Alarm Configurations

Description

Factory Setting

Range/Options

User Setting

CAN Speed Source Timeout

4 sec

0 - 999

Active Trip Count Imformtaion

Off

Off
On

Tank Content Minimum

0 GAL (US)
0 liters
0 GAL (UK)

0 - 2641 (US)
0 - 9999
0 - 2199 (UK)