Application rate options, Target rate percentage increase/decrease, Regulation valve manual open/close – TeeJet IC18 NH3 JOB COMPUTER User Manual
Page 50: Isobus job computer : ic18 nh3
44
www.teejet.com
ISOBUS Job Computer : IC18 NH3
OVER
VIE
W
SE
TUP
APPENDIX
GE
TTING ST
AR
TED
OPER
ATION
APPLICATION RATE OPTIONS
Target Rate Percentage Increase/Decrease
Figure 4-5: Target Rate Percentage Increase/
Decrease
C n t 1
0 . 0
0 . 0
0 . 0
0 . 0
0 l b N
0 . 0 0 a c
+ 5 %
0
l b / m i / a c
l b / a c
m p h
l b / a c
Target Rate Percentage Increase/Decrease Keys
increase/decrease the application target rate per the
established percentage set in the Machine Operation
setup screen under Application Rate Step. Automatic
regulation mode will automatically adjust the application
rate based on the current speed in reference to the
target rate. Preset Application Rates define up to five (5)
target rates of product being applied per hectare/acre.
These can be toggled using the Toggle Preset Target
Rate Key on the Operation Screen or Home Screen.
• To adjust the Target Rate, press the BOOST/STEP %
INCREASE/DECREASE KEYS .
Regulation Valve
Manual Open/Close
Figure 4-6: Regulation Valve Manual Open/Close
C n t 1
0 . 0
0 . 0
0 . 0
0 . 0
0 l b N
0 . 0 0 a c
0
l b / m i / a c
l b / a c
m p h
l b / a c
The regulation valve setting can be adjusted using
the Regulation Valve Open/Close Keys on the
Operation Screen. Manual regulation mode will retain an
established regulation valve setting regardless of speed.
• To adjust the regulation valve, press the
REGULATION VALVE OPEN/CLOSE KEYS .