Implement Parameters

Figure 3-17: Implement parameters

Figure 3-18: Section Width

Figure 3-19: Regulation Parameters

Implement Parameters establishes the following:

►Section Width – sets the spraying width during

application.

►Regulation Parameters – establishes adjustments to

the rough and fine valve calibrations.

Section Width

Section Width sets the spraying width during application.

Boom Section Width

Section Width establishes the boom sections widths for

each boom section.
NOTE: The number of boom sections available is set on

the Implement Parameters screen in the OEM

section.

• To select the Boom Section Width, use the number

pad or slide bar.

One-Touch Equal Widths

One-Touch Equal Widths sets all boom section widths to

the value set for #1 Boom Section.

• To set all boom section widths, press the EQUAL

SECTION WIDTH KEY .

Regulation Parameters

Regulation Parameters establishes adjustments to the

valve calibrations.
NOTE: Adjusting the Valve Calibration settings involves

significant changes and adjustments should

therefore be made in small steps.

Valve Calibration, Rough

Rough regulation value calibration allows you to

regulate the speed of the pressure regulating valve to

accommodate different application needs. Operating

conditions may necessitate a higher or lower response