25

98-05230 R0 US

ISOBUS Job Computer : IC18 NH3

OVER

VIE

W

SE

TUP

APPENDIX

GE

TTING ST

AR

TED

OPER

ATION

Operation

Figure 3-15: Operation

Figure 3-16: Step % Increase/Decrease

C n t 5

5 . 0

5 0 . 0

2 8 . 3

0 . 0

4 7 0 l b N

1 . 1 4 a c

+ 5 %

1 3 11

l b / m i / a c

l b / a c

m p h

l b / a c

Operation establishes Application Rate Step, Speed

Source and Simulated Speed.

Application Rate Step

Application Rate Step is the percent of increase/decrease

“boost” of the active application rate at which the product

is being applied.

• To select the Application Rate Step, use the number

pad or slide bar.

Speed Source

Speed Source selects whether to base the machine’s

speed on input from the CAN, an Implement or a

Simulated source. Selecting “Implement” will allow for

the configuration of pulses per 300 feet / 100 meters.

Selecting “Simulated” will allow for simulated speed to be

entered using the “Edit Value” option. Selecting “CAN”

allows for speed being supplied by the ISOBUS CAN

(usually from the TECU) to be used.

• To select the Speed Source, select an option

from the drop down menu or use the UP/DOWN

ARROWS to highlight the option.

NOTE: If “Implement” is selected, refer to the Calibrations

section for further instructions.

Simulated Speed

Simulated Speed establishes a speed to be used when

using the Simulated Speed source.

• To select the Simulated Speed, use the number pad or slide bar.