Diagnostic

Figure 3-33: Diagnostic

Figure 3-34: Test Input

Figure 3-35: Test Output

Diagnostic is used to troubleshoot input/output of the controller (sensor or actuator).

►Test Input – displays the input high and low values on the installed sensors.
►Test Output – sets the Liquid Valve PWM Dutycycle percentage as well as if

Liquid Valve Direction, Master Valve, Fill Valve and Section Valves 1-9 are on or

off.

►VT – provides information regarding the virtual terminal controller.
►TECU – provides information regarding the TECU.

Test Input

Test Input displays the input high and low values on the installed sensors.

• To reset the sensors to "0",

select TRASH CAN KEY .

Test Output

Test Output sets the Liquid Valve PWM Dutycycle percentage as well as if Liquid

Valve Direction, Master Valve, Fill Valve and Section Valves 1-9 are on or off.

Liquid Valve PWM Dutycycle

Liquid Valve PWM Dutycycle is used to test the regulating valve at different

percentages of duty cycle.

• To set the Liquid Valve PWM Dutycycle, use the number pad or slide bar.

Liquid Valve Direction

Liquid Valve Direction is used to verify the option of the Liquid valve direction is

correct to a specific duty cycle.

• Set the Liquid Valve PWM dutycycle to the percentage to be tested.
• Change the Liquid valve direction to "on" and the liquid valve will open at the

specific dutycycle.

• Change it back to off and the valve will close.

Master Valve

Master Valve is used to test if the Master Valve is operating correctly. If you

change the setting to "on", the valve will open, change it to "off" and the valve will

close.

• To set the Master Valve, select an option from the drop down menu or use the

UP/DOWN ARROWS to highlight the option.

Section Valves

Section Valves is used to test if the section Valve is operating correctly. If you

change the setting to "on", the valve will open, change it to "off" and the valve will

close.

• To set the Section Valves, select an option from the drop down menu or use

the UP/DOWN ARROWS to highlight the option.