ISOBUS Job Computer : IC18 Sprayer

Alarm Configurations

Figure 3-26: Alarm Configurations

Figure 3-27: Machine to OEM

Figure 3-28: OEM Unlock

Alarm Configurations establishes alarms on or off as well as sets their trigger level.

CAN Speed Source Timeout

CAN Speed Source Timeout establishes how long the system can operate after the

CAN speed source input is lost before the alarm is triggered.

• To select the CAN Speed Source Timeout time, use the number pad or slide

bar.

Active Trip Count Information

Active Trip Count Information sets the associated alarm to on or off. This alarm is

only displayed at powered up. It tells the user which trip counter is active.

• To select the Active Trip Count Information mode, select an option from the

drop down menu or use the UP/DOWN ARROWS to highlight the option.

Tank Content Minimum

Tank Content Minimum establishes the minimum volume level at which an alarm

will sound. Without a Tank Sensor, the minimum is determined by calculating the

difference between the established actual tank content volume and the calculated

applied content volume. With a Tank Sensor, the minimum is directly related to the

sensor reading.

• To select the minimum volume, use the number pad or slide bar.

OEM

The OEM setup menu is password protected and the settings in this menu are

directly related to the fitted OEM equipment. To obtain an access code, contact

your local dealer or TeeJet Technologies Customer Service.
To access the OEM screens:
1. From the Main Setup Screen , select MACHINE.
2. Select OEM.
3. Select the Access Code Entry Box to the right of the menu option.
4. Use the number pad or slide bar to enter the access code.
5. Select the ACCEPT KEY to complete the unlock process
6. Select from:

►Sensor presence – used to establish sensors for Flow, Liquid Pressure, Fill

Flow and the Tank

►Implement parameters – used to establish the Sprayer Mode, Number of

Sections and Circulation

►Valve setup – used to establish the Regulation Valve Type, Section Valve

Behavior and Section Valve Type

►Tank setup – used to establish maximum and minimum tank content, Auto

Filling mode and Auto Filling Offset value

►Regulation details – used to adjust the control of the regulation valve
►Clear total counters – used to delete the Total Count system counter for

Area, Volume and Time back to the default settings

NOTE: Settings are NOT automatically saved when selected. The

ACCEPT KEY must be selected to save the setting. Select the

ESCAPE KEY to escape without saving settings and return to

the previous menu. OEM