Isobus job computer : ic18 sprayer, Alarm configurations – TeeJet IC18 SPRAYER JOB COMPUTER User Manual
Page 25

20
www.teejet.com
OVER
VIE
W
SE
TUP
APPENDIX
GE
TTING ST
AR
TED
OPER
ATION
ISOBUS Job Computer : IC18 Sprayer
Alarm Configurations
Figure 3-26: Alarm Configurations
Figure 3-27: Machine to OEM
Figure 3-28: OEM Unlock
Alarm Configurations establishes alarms on or off as well as sets their trigger level.
CAN Speed Source Timeout
CAN Speed Source Timeout establishes how long the system can operate after the
CAN speed source input is lost before the alarm is triggered.
• To select the CAN Speed Source Timeout time, use the number pad or slide
bar.
Active Trip Count Information
Active Trip Count Information sets the associated alarm to on or off. This alarm is
only displayed at powered up. It tells the user which trip counter is active.
• To select the Active Trip Count Information mode, select an option from the
drop down menu or use the UP/DOWN ARROWS to highlight the option.
Tank Content Minimum
Tank Content Minimum establishes the minimum volume level at which an alarm
will sound. Without a Tank Sensor, the minimum is determined by calculating the
difference between the established actual tank content volume and the calculated
applied content volume. With a Tank Sensor, the minimum is directly related to the
sensor reading.
• To select the minimum volume, use the number pad or slide bar.
OEM
The OEM setup menu is password protected and the settings in this menu are
directly related to the fitted OEM equipment. To obtain an access code, contact
your local dealer or TeeJet Technologies Customer Service.
To access the OEM screens:
1. From the Main Setup Screen , select MACHINE.
2. Select OEM.
3. Select the Access Code Entry Box to the right of the menu option.
4. Use the number pad or slide bar to enter the access code.
5. Select the ACCEPT KEY to complete the unlock process
6. Select from:
►Sensor presence – used to establish sensors for Flow, Liquid Pressure, Fill
Flow and the Tank
►Implement parameters – used to establish the Sprayer Mode, Number of
Sections and Circulation
►Valve setup – used to establish the Regulation Valve Type, Section Valve
Behavior and Section Valve Type
►Tank setup – used to establish maximum and minimum tank content, Auto
Filling mode and Auto Filling Offset value
►Regulation details – used to adjust the control of the regulation valve
►Clear total counters – used to delete the Total Count system counter for
Area, Volume and Time back to the default settings
NOTE: Settings are NOT automatically saved when selected. The
ACCEPT KEY must be selected to save the setting. Select the
ESCAPE KEY to escape without saving settings and return to
the previous menu. OEM