Other displays:
Dive time:
0 to 999 min, counting starts and
stops at 1.2 m [4 ft] depth.
Surface time:
0 to 99 h 59 min.
Dive counter:
0 to 99 for repetitive dives.
No-decompression time: 0 to 199 min (- - after 199).
Ascent time:
0 to 99 min (- - after 99).
Ceiling depths:
3.0 to 100 m [10 to 328 ft].
Air time:
0 to 99 min (- - after 99).
Displays only in Nitrox mode:
Oxygen%: 21 - 99.
Oxygen partial pressure display: 1.2 - 1.6 bar depending on
the limit setting.
Oxygen Limit Fraction: 1 - 110% with 10% resolution (bar
graph).
Logbook/Dive Profile Memory:
Recording interval: 20 seconds (the recording interval can be set to
10s, 30s or 60s with the optional PC-interface unit and software),
records the maximum depth of each interval.
Memory capacity: approximately 36 hours of diving with 20
seconds recording interval.
Depth accuracy: 0.3 m [1 ft].
Operating Conditions
Normal altitude range: 0 to 3000 m [10000 ft] above sea level.
Operating temperature: 0°C to 40°C [32°F to 104°F].
Storage temperature: -20°C to +50°C [-4°F to +122°F].
It is recommended that the instrument be stored in a dry place at
room temperature.
NOTE! Do not leave the dive computer in direct sunlight!
Tissue Calculation Model
Suunto RGBM algorithm (developed by SUUNTO and Bruce
R. Wienke, BS, MS and PhD).
9 tissue compartments.
Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120,
240 and 480 minutes (on gassing). The off gassing halftimes
are slowed down.
Reduced gradient (variable) M values based on diving habit