Warning, Oxygen alarms in nitrox mode – SUUNTO VYTEC User Manual

Page 41

background image

39

You are able to preset alarms before the actual dive. The user program-

mable alarms can be set for maximum depth, dive time and time. The

alarms activate when:

•

The preset maximum depth is reached
• continuous beep series for 24 seconds or until any button is

pressed.

• the maximum depth blinks as long as the present depth

value exceeds the adjusted value.

•

The preset dive time is reached
• continuous beep series for 24 seconds or until any button is

pressed.

• the dive time blinks for one minute, if no button is pressed.

•

The preset alarm time is reached
• the current time is shown.
• continuous beep series for 24 seconds or until any button is

pressed.

• the current time blinks for one minute, if no button is pressed.

OXYGEN ALARMS IN NITROX MODE

Three double beeps and the backlight activated for 5 seconds

occur, when:

•

the OLF bar graph reaches 80%. The segments exceeding the

80% limit start to blink (Fig. 3.24.)

•

the OLF bar graph reaches 100%.

The blinking of the segments exceeding 80% will stop, when the OLF is

not loading anymore. At that point the PO

2

is less than 0.5 bar.

Continuous beeps for 3 minutes and the backlight activated

for 5 seconds occur, when:

•

the set oxygen partial pressure limit is exceeded. The maximum

depth is replaced with a current blinking PO

2

value. You should

immediately ascend above the PO

2

depth limit (Fig. 3.24.).

NOTE! When the backlight is turned OFF, it does not illuminate when

an alarm is activated.

WARNING!

WHEN THE OXYGEN LIMIT FRACTION INDICATES THAT THE

MAXIMUM LIMIT IS REACHED, YOU MUST IMMEDIATELY ASCEND

UNTIL THE WARNING STOPS BLINKING! Failure to take action to

reduce oxygen exposure after the warning is given can rapidly

increase the risk of oxygen toxicity and the risk of injury or death.