beautypg.com

Diving in nitrox mode 3.4.1. before diving, Display above the ceiling, Setting to – SUUNTO VYTEC User Manual

Page 32

background image

30

DISPLAY ABOVE THE CEILING

If you ascend above the ceiling during a de-

compression stop, a downward pointing arrow

will appear and a continuous beeping starts

(Fig. 3.19.). In addition, an error warning Er

reminds you that you have only three minutes

to correct the situation. You must immediately

descend to or below the ceiling.
If you continue to violate the decompression,

the dive computer goes into a permanent

Error Mode. In this mode the instrument can

only be used as a depth gauge and timer. You

must not dive again for at least 48 hours (see

also section 3.9. “Error Conditions”).

3.4. DIVING IN NITROX MODE
3.4.1. Before Diving

The Vytec has three operating modes: Air

mode for diving with standard air only, Nitrox

mode for diving with oxygen enriched (EANx)

mixtures and Gauge mode for use as bottom-

timer. The Nitrox mode is enabled in the

MODE-SET-SET PREF-MODEL submode

(see section 4.3. “Set Modes”).
If set to the Nitrox mode, the correct oxygen

percentage of the gas in your cylinder must

always be entered into the computer to en-

sure correct nitrogen and oxygen calcula-

tions. The dive computer adjusts its mathe-

matical nitrogen and oxygen calculation mod-

els. The dive computer will not accept frac-

tional percentage values of oxygen concen-

tration. Do not round up fractional percentag-

es. For example, 31.8% oxygen should be

entered as 31%. Rounding up will cause nit-

rogen percentages to be understated and will

affect decompression calculations. If there is

a desire to adjust the computer to provide

more conservative calculations, use the per-

sonal adjustment feature to affect decompres-

sion calculations or reduce the PO

2

setting to

DIVE TIME

T

C

B

m

CEILING

ASC TIME

AIR TIME

bar

Fig. 3.17. Decompres-

sion dive, above floor.

Upward pointing arrow

has disappeared and

ASC TIME label has

stopped blinking, which

means that you are in the

decompression range.

Fig. 3.18. Decompres-

sion dive, at ceiling

zone. Two arrows point

at each other (“hour

glass”). You are in the

optimum ceiling zone at

3.5 m [11 ft] and your

minimum ascent time is

5 minutes. Pressing

TIME button activates

alternative display.

DIVE TIME

T

C

B

m

STOP

CEILING

ASC TIME

MAX

TIME

AIR TIME

bar

°C