Transmission data, Warning – SUUNTO VYTEC User Manual

Page 17

background image

15

WARNING:

In case there are several divers using Vytecs with wireless trans-

mission always ensure that all divers are on different codes before

starting the dive.

The selected transmission code can later be

verified via the alternative display, by press-

ing the “TIME” button twice. If needed, the

stored code can be manually erased in this

display by pressing the “PLAN” (up) button

and then pressing “MODE” (select). The

Vytec will now erase the stored code and start

displaying “SETC” allowing a new pairing with

the transmitter.
The alternative display showing the selected

code reverts to the main display after 15

seconds in order to avoid accidental code

changes.
NOTE: In order to save battery energy the

transmitter shuts off if the pressure remains

unchanged for more than 5 minutes and it will

continue transmitting with the saved code

when any pressure change is measured. The

code number is changed if pressure is less

than 10bar [145 psi] at shutoff.

2.4.3. Transmission Data

After the pairing procedure the Vytec will

receive cylinder pressure data from the trans-

mitter. The pressure is displayed in either bars

or psi depending on the unit selection. Any

time the Vytec receives an appropriate signal

it flashes the lightning figure in the display’s

lower left corner. A pressure reading of over 360

bar [5220 psi] will display as “---“ (Fig. 2.6 b).
If the Vytec is unable to receive a valid signal

for more than one minute it will start display-

ing “FAIL” intermittently with the latest valid

pressure reading (Fig. 2.6 c).