Appendix B: Reporting codes
NX-6V2 Control Panel Installation Manual
67
Loc. Description
Default
Setting
37
Siren and system supervision
Segment 1
1 = Siren sounds for phone line cut while armed
2 = Siren sounds for phone line cut while
disarmed
3 = Siren blasts at arming
4 = Siren blasts at exit delay expiration
5 = Siren blasts at closing kissoff
6 = Siren sounds during a cross-zone verification time
7 = Siren sounds for a tam per
8 = Siren blasts one time for keysw itch, tw o times for
disarming
Segment 2
1 = Convert siren driver to voltage out
2 = Siren sounds for expander trouble
3 = Immediate restore by zone
4 = Dynamic battery test upon arming
5 = Battery missing test every 12 seconds
6 = Manual bell test during *, 4, 4 test function
7 = Manual communicator test during *, 4, 4 test
function
8 = Box tamper enabled
Segment 3
1 = Box tamper report enabled
2 = AC fail report enabled
3 = Low battery report enabled
4 = AUX pow er over current report enabled
5 = Siren supervision report enabled
6 = Telephone line cut report enabled
7 = Ground fault detection report enabled
8 = Expander trouble report enabled
Segment 4
1 = Failure to communicate report enabled
2 = Log full report enabled
3 = Autotest report enabled
4 = Start and end programming report enabled
5 = End dow nload report enabled
6 = Sensor low battery report enabled
7 = Sensor missing report enabled
8 = First to open/last to close enabled
Segment 5
1 = Lost clock service LED enabled
2 = Zone doubling enabled
3 = Disable on-board eight zones
4 = Enable tw o trips on the same cross-zone to
activate the alarm
5 = Disable bypass reports for force armed zones
6 = Reserved
7 = Clock uses internal crystal
8 = Disable temporal siren on fire
Segment 6
1 = Enable tw o-w ire smoke detector
2 = Reserved
3 = Enable zone activity in hours (not days)
4 = Enable Daylight Saving Time (DST)
5 = Reserved
6 = Disable Clean Me report
7 = Disable start/end test report
8 = Enable auto LED extinguish
Segment 7 = Reserved
38
Swinger shutdown count
1
39
Keypad sounder control
Segment 1
1 = Keypad sounds for telephone line cut w hen in the armed state
2 = Keypad sounds for telephone line cut w hen in the disarmed state
3 = Keypad sounds upon AC pow er failure
4 = Keypad sounds upon low battery detection
5 = Keypad sounds during cross zone trip time
6 = Keypad sounds for tamper alarm
7 = Reserved
8 = Keypad sounds for expander trouble
40
System timers
Segment 1 = Dynamic battery test duration (0 to 255)
0 (minutes)
Segment 2 = AC failure report delay (0 to 255
minutes)
5 (minutes)
Segment 3 = Pow er up delay (0 to 60)
60 (seconds)