Location 84 - Daylight saving time
Location 84 has four segments of numerical data. Use this location to program
when daylight saving time begins and ends. This will happen at 2:00 a.m. on the
day programmed. The default is to begin daylight saving time on the second
Sunday in March and end on the first Sunday in November.
Segment 1 -
Daylight saving time starting month (1 to 12). Default is 3.
Segment 2 -
Daylight saving time starting Sunday (1 to 4, first to fourth). Default is 2.
Segment 3 -
Daylight saving time ending month (1 to 12). Default is 11.
Segment 4 -
Daylight saving time ending Sunday (1 to 4, first to fourth). Default is 1.
Locations 85 to 87 - Reserved
Locations 88 to 91 - Partition account codes and
features.
If a location is left unprogrammed, the feature for partition 1 and account code for
the phone number will be used.
Locations 88 - Partition 1 account code
Location 88 has six segments of numerical data. If the account code is less than
six digits, program a 10 in the segment immediately after the last digit of the
account number. If the account codes is six digits long, program all six segments.
Location 89 - Partition 2 account code
Location 89 has six segments of numerical data. If the account code is less than
six digits, program a 10 in the segment immediately after the last digit of the
account number. If the account code is six digits long, program all six segments.
Location 90 - Partition 2 feature and reporting selection
Location 90 has five segments of feature selection data. Use this location to
enable certain features that are accessed or visible to the user from the system
keypad. In addition, certain communicator reports are enabled at this location.
Each of these features can be enabled by partition (Location 23).
Location 91 - Partition 2 entry and exit times
Location 91 has six segments of numerical data. Use this location to program the
entry/exit times for partition 2. There are two separate entry/exit times (Location
24).