Interlogix NX-6V2 Rev C Installation Manual User Manual
Page 33

Chapter 2: Reporting codes
NX-6V2 Control Panel Installation Manual
29
Zone type
Description
6. Instant
Creates an instant alarm whenever it is tripped and the armed LED is
on.
7. 24-hour silent
Creates an instant silent alarm regardless of the armed state of the
control panel. It does not display on the keypad.
8. Fire
Illuminates the Fire LED and sounds the temporal siren each time the
zone is shorted. The Fire LED flashes rapidly indicating a problem if
the zone is open.
9. Entry/exit delay 2
A trip starts entry delay 2. The lack of a trip during exit delay enables
the automatic bypass or instant mode if programmed.
10. 24-hour silent
supervised
Creates an instant silent alarm regardless of the armed state of the
control panel. It displays on the keypad.
11.Reserved
12. Interior follower with
cross zone
Instant when the system is armed and no entry or exit delay is being
timed. It is delayed during entry and exit delay times. If a cross zone is
not being timed, it starts a cross zone timer. If a cross zone is being
timed, it creates an instant alarm. It automatically bypasses when
enabled in Segment 1 of Location 23.
13. Instant entry guard
Creates an instant alarm whenever it is tripped and the Stay LED is
off. It starts an entry delay type 2 if it is tripped, the system is armed,
and the Stay LED is on.
14. Entry/exit delay 1
with group bypass
A trip starts entry delay 1. This zone bypasses when the group bypass
command is entered at the keypad. The lack of a trip during exit delay
enables the automatic bypass or instant mode if programmed.
15. Interior follower with
group bypass
Instant when the system is armed and no entry or exit delays are
being timed. It is delayed during entry/exit delay times. It bypasses
when the group bypass command is entered at the keypad. It
automatically bypasses if enabled in Segment 1 of Location 23.
16. Instant with group
bypass
Creates an instant alarm whenever it is tripped and the Armed LED is
on. Bypasses when the group bypass command is entered at the
keypad.
17. Entry/exit delay 1
with tamper
A trip starts entry delay 1. The lack of a trip during exit delay enables
the automatic bypass or instant mode if programmed. Is used to
enable the tamper on a wireless transmitter.
18. Interior follower with
tamper and autobypass
Instant when the system is armed and no entry or exit delay is being
timed. It is delay during entry and exit delay times. It automatically
bypasses if enabled in Segment 1 of Location 23. Is used to enable
the tamper on a wireless transmitter.
19. Instant with tamper
Creates an instant alarm whenever it is tripped and the Armed LED is
on. Is used to enable the tamper on a wireless transmitter.
20. Entry/exit delay 2
with tamper
A trip starts entry delay 2. The lack of a trip during exit delay enables
the automatic bypass or instant mode if programmed. Is used to
enable the tamper on a wireless transmitter.