EVCO EVXS815P9 Installer manual User Manual
Page 7
EVCO S.p.A.
EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134
page 7 of 60
evaporator fan
8 A
door heating elements/condenser fan
16 A
cabinet light/needle probe heating/UV light
8 A
Communication port
EVXS815
serial port with MODBUS communication protocol
•
Other features
EVXS815
clock
•
signal buzzer and alarm
•
direct loads connection
except for the utility managed by the fifth digital output
management of three types of backlight
•
management of blast chilling and storage/deep freezing
and storage cycles
•
management of temperature/time controlled operation
cycles
•
hard/soft operating cycles management
•
management of the test regarding correct insertion of
the needle probe
•
memorisation of the defrosting interval
•
management of temperature alarms
•
compressor operating hours count
•
“HACCP” function
•
"keyboard lock" function
•
configuration parameters access password
•
restoring the factory settings
•
Codes
EVXS815
codes
EVXS815P9