EVCO EVXS815P9 Installer manual User Manual
Page 31

EVCO S.p.A.
EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134
page 31 of 60
P0
0
1
- - - -
0
probe type
0 = PTC
1 = NTC
P1
0
1
- - - -
1
°C decimal point
1 = yes
P2
0
1
- - - -
0
temperature unit of measurement (2)
0 = °C
1 = °F
P3
0
1
- - - -
1
enabling the needle probe
1 = yes
P4
0
1
- - - -
1
enabling the evaporator probe
1 = yes
P8
0
250
ds
5
delay displaying temperature variation detected by the
probes
P9
- - - -
- - - -
- - - -
- - - -
reserved
Par.
Min.
Max.
Unit
Default
Main regulator
r0
0.1
15.0
°C/°F (1)
2.0
parameters differential r7, r8, r9, r10, r11 and r12
r1
1
500
min
90
duration of time-controlled blast chilling
r2
1
500
min
240
duration of time-controlled deep freezing
r3
-50.0
99.0
°C/°F (1)
3.0
temperature-controlled blast chilling end time temperature;
also end temperature of the temperature-controlled soft
deep freezing phase (temperature detected by the needle
probe); see also parameter r5
r4
-50.0
99.0
°C/°F (1)
-18.0
temperature-controlled deep freezing end temperature
(temperature detected by the needle probe); see also
parameter r6
r5
1
500
min
90
maximum duration of temperature-controlled blast chilling;
see parameter r3 also
r6
1
500
min
240
maximum
duration
of
temperature-controlled
deep
freezing; see parameter r4 also