EVCO EVXS815P9 Installer manual User Manual
Page 34

EVCO S.p.A.
EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134
page 34 of 60
C0
0
240
min
0
minimum time between restoring the power supply after a
power cut, occurring during an operating cycle and
compressor switch-on
C1
0
240
min
5
minimum time between two consecutive compressor switch-
ons (3)
C2
0
240
min
3
minimum
time
between
compressor
switch-off
and
successive switch-on (3)
C3
0
240
s
0
compressor switch-on minimum duration
C4
0
240
min
10
duration of compressor switch-off during the cabinet probe
error (“Pr1” code) that occurs during storage; see also
parameter C5
C5
0
240
min
10
duration of compressor switch-on during the cabinet probe
error (“Pr1” code) that occurs during post blast chilling
storage; see also parameter C4
C9
0
240
min
30
duration of compressor switch-on during the cabinet probe
error (“Pr1” code) that occurs during post deep freezing
storage; see also parameter C4
Par.
Min.
Max.
Unit
Default
Defrosting (5)
d0
0
99
h
8
defrosting interval (6)
0 = defrosting will never be activated at intervals