EVCO EVXS815P9 Installer manual User Manual
Page 37

EVCO S.p.A.
EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134
page 37 of 60
A13
0
1
- - - -
1
memorisation of the temperature-controlled blast chilling or
temperature-controlled deep freezing non concluded within
maximum duration alarm (“tiME”)
1 = yes
Par.
Min.
Max.
Unit
Default
Evaporator and condenser fan
F0
0
2
- - - -
1
evaporator fan activity during pre-cooling, blast chilling and
deep freezing
0 = off
1 = on; see also parameters F16 and F17
2 = parallel to the compressor; see also parameters F9
and F17
F1
-50.0
99.0
°C/°F (1)
-1.0
evaporator temperature above which the evaporator fan is
off during storage (only if parameter F2 is set at 3); see
also parameter XS8(10)
F2
0
3
- - - -
3
evaporator fan activity during storage
0 = off
1 = on
2 = parallel to the compressor; see also parameter F9
3 = on; see also parameter F1
F3
0
15
min
2
duration of evaporator fan standstill (the compressor can be
on during evaporator fan standstill, the defrosting output
will remain deactivated and the evaporator fan will remain
off)
XS8
0.1
15.0
°C/°F (1)
2.0
F1, F16 and F17 parameters differential
F9
0
240
s
0
evaporator fan switch-off delay from compressor switch off
(only if parameter F0 and/or parameter F2 are set at 2)
F12
0
240
s
30
condenser fan switch-off delay from compressor switch-off
(11)
F15
0
240
s
15
evaporator fan delay from door closure, i.e. from the
deactivation of the door micro switch input