TECHNICAL DATA

14.1

Technical data

Purpose of the devices:

blast chiller controllers

Esecuzione:

open frame board

Dimensions:

EVX802

EVX812

EVX805

EVX815

156.0 x 45.0 x 44.2 mm (6.141

x 1.771 x 1.740 in; L x H x D).

156.0 x 45.0 x 48.7 mm (6.141

x 1.771 x 4.869 cm; L x H x D).

Installation:

back panel via M3 studs

Protection rating:

IP00

Connections:

6.3 mm faston (0.248 in, power supply and outputs), screw

terminal board (inputs), 6 pole connector (serial port).

Temperature of use:

from 0 to 55 °C (from 32 to 131 °F)

Storage temperature:

from -25 to 60 °C (from -13 to 140 °F)

Humidity for use:

from 10% to 90% relative humidity without condensate

Pollution situation:

2

Power supply:

EVX802

EVX812

EVX805

EVX815

230 VAC (±10%), 50/60 Hz,

2.3 VA max. or 115 VAC

(±10%), 50/60 Hz, 5 VA max.

230 VAC (±10%), 50/60 Hz,

2.8 VA max. or 115 VAC

(±10%), 50/60 Hz, 5 VA max.

Overvoltage category:

III

Clock:

EVX802

EVX812

EVX805

EVX815

not available.

incorporated

(with

condenser)

not available.

incorporated

(with

condenser)

Battery autonomy in the event of a power-cut: 24 h with battery

fully charged

Battery charging time: 2 min (the battery is charged by the device

power supply)