Configuration using the web user interface, Configuration overview – Comtrol ES9528-XT User Guide User Manual
Page 29

RocketLinx ES9528 and ES9528-XT User Guide: 2000508 Rev. G
Configuration Overview - 29
Configuration Using the Web User Interface
The ES9528 provides in-band and out-band configuration methods:
•
Out-band management means that you configure the ES9528 using the RS-232 console cable and the
Command Line Interface (CLI) to access the ES9528 without attaching an admin PC to the network. You
can use out-band management if you lose the network connection to the ES9528. The CLI and Telnet are
discussed in
Configuration Using the Command Line Interface (CLI)
•
In-band management means that you connect remotely using the ES9528 IP address through the
network. You can remotely connect with the ES9528 embedded Java applet web user interface or a Telnet
console and the CLI. The ES9528 provides HTTP web user interface (
user interface (
) for web management.
Configuration Overview
This subsection discusses a minimum level of configuration required to operate the ES9528.
1.
If you have not done so, install the hardware, see
2.
If you are planning on using in-band management, you need to program the ES9528 IP address to meet
your network requirements. The easiest way to configure the IP address is using a Windows system and
PortVision DX, see
Configuring the Network Settings
3.
Configure other features as desired. You can refer to the
configuration information or use these links:
•
•
•
•
•
•
•
•
•
•
•
•
•
•