Comtrol ES9528-XT User Guide User Manual
Page 128

128 - Using the Serial Console
RocketLinx ES9528 and ES9528-XT User Guide: 2000508 Rev. G
Configuration Using the Command Line Interface (CLI)
11. Press Enter.
12. Log in to the switch. The default user name is admin, password, admin.
a.
Type the login and press the Enter key.
b.
Type the password and press the Enter key.
13. If necessary, configure the IP address for your network. The following example shows how to program an
IP address of 192.168.11.252 with a Class B subnet mask (255.255.0.0).
For more information about using the CLI, see
Command Line Interface Introduction
Switch login: admin
Password:
Switch (version 1.4b_b4-20140902:16:03:22).
Switch>
Switch> enable
Switch# configure terminal
Switch(config)# int vlan1
Switch(config-if)# ip address 192.168.11.252/16