RAM CLEAR AND STATUS CLEAR OPERATION
1. Turn the Power Switch to OFF.
2. Turn the RAM Clear Switch to ON.
3. Turn all the Clerk Keys to OFF for a RAM Clear. Or turn one of the
clerk keys to ON for a Status Clear.
4. Turn the Mode Lock to any one of the positions below;
SET, LOCK, MGR, [3t Z ...... (for zero suppress of:0.00)
(NOTE; If the Mode Lock is turned to other positions, the zero
suppress will be as follows:
REG ......... for zero suppress of 0 as in IT or JA
version
X ........... for zero suppress of 0.0 as
in
TA version)
5. Turn the Power Switch to ON.
Now a RAM Clear operation is fininshed and the Standard S.F.K.C. have
automatically been programmed.
("Standard S.F.K.C" is shown as the
STANDARD KEYBOARD LAYOUT in the OWNERS MANUAL.)
6. Keep the RAM Clear Switch to ON if a SFKC programming (to change partly
or entirely from the Standard S.F.K.C. feature) follows. Turn the RAM
Clear Switch to OFF if not.
- 6 A