FUNCTION OF EACH KEY

RECEIPT

off

[

ON

Receipt ON/OFF Switch

This switch has two positions available — 'OFF' position and 'ON'

poisition. When in the 'OFF' position, no receipt is issued from

the register and sales are printed on the audit roll only. When
the switch is turned to the 'ON' position, sales are printed on both

the receipt roll and audit roll, then a receipt is issued which is

torn off and given to the customer.

No-sale Key

This key is used, when the Mode Lock is in the REG position, to open
the cash drawer while the machine is outside a sale. To operate,
depress this key once. A non-add number may usually be entered prior
to a no-sale operation. However, it can be programmed to prohibit

it when a no-sale is operated.

I VALIDATE] Validation Key

This key is used to over print a validation slip.

To operate, after registering an item or finalizing a sale, insert
a slip into the validation slot and depress the I VALIDAT

e

I key.

The item, the amount, and the date and/or consecutive number will
be printed on one line on the slip.

The system option provides program selections as to the printing
position, single- or multi-validation, validation compulsion on some

transaction keys, etc.

If the SLIP Lamp flashes, it means that validation compulsion is

programmed for the last item entered. In this case, insert a slip

into the validation slot and depress the IVALIDATFI key; no other

operation is allowed until the compulsory validation has been done.

Receipt Feed Key

This key is used to advance the receipt roll. It is operated by
depressing the key and holding it in that position until the paper
has advanced to the required position.

[JF| Journal Feed Key

This key is used to advance the audit roll in the same fashion as

the RF key. These two keys are useful if the cashier, due perhaps
to an interruption whilst ringing up a sale, is unsure which items

have already been entered. By using the feed key the cashier can

see which figures have actually been printed.

jPR OPEN] Preset Open Key

This key is used to modify the status of preset department keys.

When the | PR OPE^I key is depressed prior to depressing a preset

department key (either before or after the numeric entry), the preset