85

The following table shows other operating irregularities which are not displayed with an error
message.

Error Possible

cause

Remedy

Suction plate not correctly locked

Lock suction plate correctly

Nominal oven temperature too high

Select lower temperature and increase
cooking time

Not pre-heated

Always pre-heat Combis

Bypass pipe greasy

Clean bypass

Uneven browning

Incorrect accessories, containers

Use suitable accessories and
containers

Control elements not illuminated and
do not react when switched on

No power connection, external failsafe
triggered

Call customer service

Appliance does not react to information
entered

Software has hung itself up

Hold down the ON/OFF switch for 5
seconds or disconnect appliance for 5
seconds

Appliance cannot be switched on or
off

ON/OFF has been locked for 3
seconds

Try again after 3 seconds

Oven is not lit inside

Oven light fault

Call customer service

Steam measuring line blocked

Clean steam measurement line; see
“Daily servicing and maintenance”

Water sprays from air outlet when door
is closed

Appliance drain blocked

Clean outflow

Water sprayed out of steam generator
into oven during operation

Automatic rinsing of steam generators
has not been carried out for some
time, i.e. it is continually deselected

Activate automatic rinsing

The next date change or the following
day will be adequate

Water inside the oven

Outflow blocked

Descale

Outflow connection blocked or covered

Remove object

Water running out of base of appliance

Outflow blocked

Rinse condenser and outflow
thoroughly, clean/check own drain
system

Incorrect cleaning agent

Use genuine CONVOClean and
CONVOCare cleaning agents

Black marks inside oven

Water hardness too high

See Water Quality Recommendations
in Warranty

Water pressure too low

Increase pressure at installation
location

Incorrect cleaning agent

Switch to CONVOClean

Automatic cleaning (CONVOClean
system) gives poor cleaning results

Degree of soiling incorrectly set

Select higher cleaning level

Caution:

If an error cannot be rectified with the aid of this list, please contact your
qualified Cleveland Range authorized service representative.