Maintenance and Cleaning

76


COMBI ATMOSPHERIC STEAM GENERATOR DESCALING PROCEDURE

(For DISSOLVE® Descaler Solution Part No. 106174)

This procedure will take approximately 3 hours to complete.

1. Turn ON the Combi at the Control Power Service

Disconnect switch located below the hand
shower. See Figure 6-2.

2. Turn ON the COMBI with the ON / OFF key

.

3. Open the door to the cooking compartment.

4. Run a manual steam generator rinse cycle.

To Empty and Rinse the Steam Generator:

a. Press the Smart Key

.

b. Select “Manual steam generator rinse”

with the Selector Dial

6019002_00

D

.

c. Confirm “Yes” with the Smart Key

.

d. Steam generator will rinse and begin to

refill to operating level.

4. Remove the cap from the descale port located at

the top of the unit (See Figure 6-1).

NOTE: DO NOT HEAT THE COMBI DURING
DESCALING.

5. While the unit is filling with water, use a funnel

(NOT INCLUDED) to add 3/4 gallon of
DISSOLVE

®

descaler solution into the

descaling port of 20.20 COMBIs, and 1/2 gallon
for all other models
• While adding liquid to the unit through the

descaler inlets, pour slowly to avoid
overflow.

• Wipe up any spills at once to avoid etching.

6. After the automatic fill cycle has ended, turn OFF

the Combi with the ON / OFF key

, and at the

Control Power Service Disconnect switch located
below the hand shower. See Figure 6-2.

WARNING

This procedure is slightly different depending on the model

being descaled. This entire procedure should be read and fully

understand as it applies to the model being descaled, before

beginning the actual descaling operation.

Figure 6-1 Descaling Port

Located at Right Rear of the