beautypg.com

Aerco, Appendix g, Leg e nd – AERCO BMK 3.0 LN Nat. Gas APRIL 2009 User Manual

Page 102

background image

APPENDIX G

G-2

N

OR

T

H

VALE

, N

J 07647

IN

T

E

RN

A

T

IONA

L, INC

.

APPD

.

DWN.

B

Y

SC

AL

E

DA

T

E

MC

DA

T

E

SD

06

15

06

AERCO

S

D

-A

-6

82

C

REV

.

BE

NCH

MARK

3

M

IL. BTU LO

W NOx

GA

S FIRED

BOILE

R

M

ULTI

PLE UNI

T INSTA

LLATI

ON

5) THIS IS A TY

PICA

L

INSTA

LLATIO

N DRA

WING

. LO

CAL CO

DES AN

D AUTH

ORIT

IES SHO

ULD BE

C

ONSU

LTED

.

2) SHE

LL DRAI

N VALVE

A

ND CON

DEN

SATE D

RAIN TR

AP SHO

ULD BE

A

RRAN

GED TO

P

ERM

IT THE FL

UIDS TO

D

RAIN

4) LOCAT

E WAT

ER INLE

T AND OU

TLET

F

ITTIN

GS (i

.e. UNI

ONS, EL

BOWS

, ETC.)

A

M

INIMU

M OF 6'

' FROM

B

OILER

ELE

CTRIC

C

ONN

ECTIO

NS (SE

RVICE

S

W

ITC

HES, CO

NDU

IT BOXE

S) SHO

ULD LIK

EWIS

E

1) FO

R ACTU

AL SIZE

S AND LO

CATIO

NS OF

P

IPING

AN

D OTH

ER CON

NECT

IONS

T

O THE BO

ILER,

S

EE DIME

NSIO

NAL DR

AWIN

G (AP-A

-802).

F

REEL

Y, BY GRA

VITY,

T

O A CONV

ENIEN

T FLOO

R DRA

IN. RELIE

F VALVE

S

HOUL

D BE PIPE

D VERT

ICALL

Y TO A

FITTI

NGS TO

P

REVE

NT INTE

RFER

ENCE

W

ITH R

EMOV

AL OF BO

ILER PA

NELS AN

D COV

ERS. ALL PI

PING AN

D

6) WHEN

A

VAILA

BLE GA

S PRESS

URE

IS

G

REAT

ER THA

N 2.0 PSIG

, A LOCK

-UP STY

LE REG

ULAT

OR MUS

T BE INST

ALLE

D

DOW

NST

REAM

O

F THE 2" MA

NUAL

S

HUTO

FF VAL

VE TO BR

ING THE

G

AS PRE

SSUR

E DOW

N TO 2.0 PS

IG.

P&T

AUTO

MATI

C

AIR VEN

T

AIR

SEP

ARAT

OR

1-1

/2" NPT

DR

AIN CO

NN.

H

EIGHT

1

8'

' AB

OVE FLO

OR.

3) ALL (*) ITE

MS ARE

INCLUD

ED SEP

ARAT

ELY IN SH

IPME

NT FRO

M FAC

TORY

.

BE 6'

' AWAY

F

ROM

S

IDE PAN

ELS.

NOTE

S:

* CO

NDEN

SATE

D

RAIN TR

AP

PR

ESSU

RE

RE

DUCI

NG

FILL VAL

VE

DIAPH

RAG

M TYPE

EXPA

NSIO

N TANK

BAC

KFLO

W PRE

VENTE

R

LI

N

E

SI

Z

E

BYPA

SS

HE

ATING

SY

STEM

S

UPPL

Y

SU

PPLY

WA

T

E

R

S

YSTE

M

PU

M

P

CHEC

K

VALVE

(TYP.

)

H

EATI

NG

SYST

EM

RETU

RN

* 2

" M

ANUA

L

SHUT

OFF

VALVE

REL

IEF

V

A

LVE

(

T

Y

P.

)

ISOLA

T

ION VA

LVE

BA

LA

NC

IN

G VA

LV

E

TEM

PERA

TURE

G

AUGE

LEG

E

ND

Y ST

R

A

IN

E

R

UNIO

N

PRE

SSUR

E &

P&T

DR

IP TRA

P

GAS SU

PPLY

P&T

7) EA

CH CON

DENS

ATE PO

RT CAN

B

E PIPED

INDIVI

DUAL

LY TO MA

IN DRAI

N.

(SEE N

O

T

E 7

)

* 2

"

M

A

N

U

A

L

SH

U

T

OF

F

VALVE

(T

O

B

O

IL

E

R

)

D

iagr

am

1

GAS SU

P

PLY

(SEE N

O

T

E

8)

M

A

IN

T

A

IN

A

R

E

GU

LA

T

E

D

4

" W.C

. GAS PR

ESSU

R

E

AT

M

AX BT

U

/H

R

IN

PU

T

DR

IP

T

R

A

P

8) A GA

S REGU

LATO

R IS MAN

DATO

RY FOR

T

HE STA

TE OF MA

SSAC

HUSE

TTS, R

EGAR

DLESS

O

F SUPP

LY PRE

SSUR

E.

SEE DI

AGRA

M 1

A

T

M

A

XI

M

U

M

BTU/

HR I

N

PUT

,

M

A

INT

A

IN

M

INIM

UM

NAT

URA

L

GAS

P

R

ESSU

RE

A

T

3

.5

" W.

C.

(

F

M

G

AS

T

R

AIN)

/4

.0

"

W.C. (

IRI GAS

T

R

AIN)

M

A

X

G

AS PRE

SSURE = 2

.0

P

S

IG

.

(S

E

E

N

O

TE

6

)